CEI ASTM BS DIN multibrin 4 8 12 16 35 conducteurs en cuivre ignifuges à noyau blindé non blindé non blindé CPR contrôle de signal flexible fil PVC/LSZH

CEI ASTM BS DIN multibrin 4 8 12 16 35 conducteurs en cuivre ignifuges à noyau blindé non blindé non blindé CPR contrôle de signal flexible fil PVC/LSZH

Présentation Description du produit Application Le câble de commande convient à la connexion d'équipements de contrôle e
Overview
Informations de base.
Matériau du noyau du filFil de cuivre rouge ou nu
AttestationOIN, CCC, CE, RoHS, VDE
ModèleKvv/Kvv22/Kvvr/Zc-Kvv
MarqueYantong
StandardISO9001, ISO14001, ASTM BS DIN GB
Terme commercialGousset, Crf, CIF, EXW
ÉchantillonGratuit
Service après-venteSoutien
Délai de livraison5-30 Travail
MOQ500 mètres
Délai de paiement 2Dépôt de 30 % + 70 % L/C à vue irrévocable
Conditions de paiement 1Dépôt de 30 % + solde avant l'expédition
Le nombre de cœursMulticœur
Blindé ou pasBlindé ou non blindé
Avec AlCu
Type d'armureRuban ou fil
CouleurNoir/Rouge/Jaune/Bleu
Durée de vie50 ans
Gaine ou pasGainé ou non gainé
Forfait TransportForfait navigabilité standard
spécification37*1,5 19*2,5 19*1,5 7*2,5

25 dbr Multi-core cable (d): D > 20 d.br5.4 The selection of the delivery tray is based on the premise that the tube diameter meets the requirements of the bending radius of the installed cables, and its size should be compatible with the delivery length and specifications of the cables.br6. Packaging of coiled cables (wires)br6.1 Disk loading requirementsbr6.1.1 Generally, cables (wires) should be delivered in coils one by one, and the length should not be less than 100 m.br6.1.2 It is allowed to deliver short cables (wires) in platters with a length of less than 20 m, and the quantity should not exceed 10% of the total delivery length.br6.1.3 According to the agreement between the two parties, it is allowed to deliver cables (wires) of any length.br6.1.4 Meter counters shall be used for length measurement, and the error shall not exceed ± 0.5%.br6.1.5 The products are neatly arranged in a tray, and the distance between the outermost layer and the edge of the tray should not be less than 50 mm.br6.1.6 If multiple cables (wires) are allowed to be delivered as a platter, the length of each cable (wire) from inside to outside shall be indicated on the certificate of conformity.br6.2 Disposal of cable (wire) endbr6.2.1 The end of the coiled cable (wire) should pass through the oblique hole on the side plate of the delivery tray, and the length should not be less than 300mm.br6.2. 2 The cable (wire) head should be reliably sealed to ensure that the cable (wire) end does not enter water.br6.2.3 If multiple platters are allowed to be delivered, the tail end of the previous one and the front end of the rear root shall be connected by ropes.br6.3 Protectionbr6.3.1 After the cable (wire) is coiled, its outermost surface should be covered with a layer of moisture-proof paper, felt or burlap as an inner protective layer.br6.3.2 Appropriate outer protective layer should be used for protection outside the inner protective layer. The outer protective layer can be made of bamboo curtains, bamboo guard boards or other equivalent materials, and its width should be 5 mm to 10 mm smaller than the inner width of the corresponding delivery tray. mm, its length should be determined according to the loading capacity.br6.3.3 According to the agreement of both parties, it is allowed to use any method of protection.br6.3.4 Two layers of plastic strapping (with a width of about 15 mm and tightened tightly) should be applied outside the outer sheath./p>